﻿<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>LEONARDO &#8211; Varel Srl</title>
	<atom:link href="https://www.varelit.com/en/categoria/leonardo-en/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.varelit.com/en/</link>
	<description>Apparecchiature per rifasamento &#124; Varel Srl</description>
	<lastBuildDate>Wed, 30 Oct 2019 16:24:53 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.5.3</generator>

<image>
	<url>https://www.varelit.com/wp-content/uploads/2018/03/cropped-logoicona-1-32x32.png</url>
	<title>LEONARDO &#8211; Varel Srl</title>
	<link>https://www.varelit.com/en/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>JOLLY</title>
		<link>https://www.varelit.com/en/prodotto/jolly/</link>
		
		<dc:creator><![CDATA[varel]]></dc:creator>
		<pubDate>Sat, 09 Dec 2017 13:04:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.varelit.com/prodotto/jolly/</guid>

					<description><![CDATA[JOLLY]]></description>
										<content:encoded><![CDATA[<p>Easy installing power factor correction battery unit for Leonardo devices, thanks to its plug and play connectors that guarantee easiness and safety. Made in galvanized metal sheet with fixing screws included. Three versions with different power from 7,5 to 31,5 kVAr in ST &#8211; MH and AT typologies. TECHNICAL DATA Disconnectable three-pole fuse-box. Contactor equipped with limiting resistors and suitable to the insertion of capacitive banks. Indicator light for melted fuse. Fast plug and play connector for insertion into the device. ST (standard) or MH (reinforced) single-phase capacitors in a delta connection, or three phase AT (nitrogen) capacitors Reference standards: EN61921,IEC60439,IEC60831-1</p>
<p><a href="https://www.varelit.com/wp-content/uploads/2019/10/Jolly-1-MH-2019-En-1.pdf" target="_blank" rel="noopener noreferrer">Technical Data Shet Jolly-1</a></p>
<p><a href="https://www.varelit.com/wp-content/uploads/2019/10/Jolly-2-MH-2019-En-1.pdf" target="_blank" rel="noopener noreferrer">Technical Data Shet Jolly-2</a></p>
<hr />
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LEONARDO D</title>
		<link>https://www.varelit.com/en/prodotto/leonardo-d/</link>
		
		<dc:creator><![CDATA[varel]]></dc:creator>
		<pubDate>Sat, 09 Dec 2017 13:04:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.varelit.com/prodotto/leonardo-d/</guid>

					<description><![CDATA[LEONARDO D]]></description>
										<content:encoded><![CDATA[<p>Maximum installable power 275 kVAr.</p>
<p>Fully modular automatic power factor correction equipment LEONARDO type in painted metal plate RAL 7035, on a galvanized metal sheet base and double front panels with screw fastening.</p>
<p>Dimensions (mm) 1160x685x400 HxWxD</p>
<p>Possibility to install up to 14 different Jolly units of different powers.</p>
<p>Available on request: IP 54 protection, 230 V rated power supply</p>
<p>TECHNICAL DATA:</p>
<p>&#8211; Three-pole disconnector with a door blocking system.</p>
<p>&#8211; Automatic regulator RDM 6 standard up to 6 batteries, with backlit LCD display for a better vision of the data.</p>
<p>&#8211; Auxiliary circuits 400 V (230V or 110 V available on request).</p>
<p>&#8211; Fuse protection for the auxiliary circuits.</p>
<p>&#8211; Rapid plug and play connectors for inserting the Jolly units.</p>
<p>&#8211; Connection with fireproof N07VK cables.</p>
<p>&#8211; Natural ventilation.</p>
<p>&#8211; Internal wall mounted installation Cable entry from the top.</p>
<p>&#8211; Reference standards CEI EN61921, IEC60439, IEC60831-1</p>
<hr />
<p><a href="/wp-content/uploads/2017/09/LND D 2014.pdf" target="_blank" rel="noopener">LND D 2014.pdf</a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LEONARDO F</title>
		<link>https://www.varelit.com/en/prodotto/leonardo-f/</link>
		
		<dc:creator><![CDATA[varel]]></dc:creator>
		<pubDate>Sat, 09 Dec 2017 13:04:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.varelit.com/prodotto/leonardo-f/</guid>

					<description><![CDATA[LEONARDO F]]></description>
										<content:encoded><![CDATA[<p>Maximum installable power 350 kVAr.</p>
<p>Fully modular automatic power factor correction equipment LEONARDO type in painted metal plate RAL 7035, on a galvanized metal sheet base and double front panels with screw fastening.</p>
<p>Dimensions (mm) 1660x685x400 HxWxD</p>
<p>Possibility to install up to 14 different Jolly units of different powers.</p>
<p>Available on request: IP 54 protection, 230 V rated power supply</p>
<p>TECHNICAL DAT:</p>
<p>&#8211; Three-pole disconnector with a door blocking system.</p>
<p>&#8211; Automatic regulator RDM 6 standard up to 6 batteries, with backlit LCD display for a better vision of the data.</p>
<p>&#8211; Auxiliary circuits 400 V (230V or 110 V available on request).</p>
<p>&#8211; Fuse protection for the auxiliary circuits.</p>
<p>&#8211; Rapid plug and play connectors for inserting the Jolly units.</p>
<p>&#8211; Connection with fireproof N07VK cables.</p>
<p>&#8211; Natural ventilation.</p>
<p>&#8211; Internal wall mounted installation Cable entry from the top.</p>
<p>&#8211; Reference standards CEI EN61921, IEC60439, IEC60831-1</p>
<hr />
<p><a href="/wp-content/uploads/2017/09/LND F 2014.pdf" target="_blank" rel="noopener">LND F 2014.pdf</a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LEONARDO  A</title>
		<link>https://www.varelit.com/en/prodotto/leonardo-a/</link>
		
		<dc:creator><![CDATA[varel]]></dc:creator>
		<pubDate>Sat, 09 Dec 2017 13:04:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.varelit.com/prodotto/leonardo-a/</guid>

					<description><![CDATA[LEONARDO A]]></description>
										<content:encoded><![CDATA[<p>Maximum installable power 50 kVAr. Fully modular automatic power factor correction equipment LEONARDO type in painted metal plate RAL 7035, double front panel with screw fastening.<br />
Dimensions (mm) 480x342x400 HxWxD<br />
Possibility to install up to 4 different Jolly units of different powers.<br />
Available on request: IP 54 protection, 230 V rated power supply</p>
<p>TECHNICAL DATA:<br />
&#8211; Three-pole disconnector with a door blocking system.<br />
&#8211; Automatic regulator RDM 4 standard up to 4 batteries, with backlit LCD display for a better vision of the data.<br />
&#8211; Auxiliary circuits 400 V (230V or 110 V available on request).<br />
&#8211; Fuse protection for the auxiliary circuits.<br />
&#8211; Rapid plug and play connectors for inserting the Jolly units.<br />
&#8211; Connection with fireproof N07VK cables.<br />
&#8211; Natural ventilation (LNDA-B-C) or forced ventilation with fan on the top (LND-D-F).<br />
&#8211; Internal wall mounted installation<br />
&#8211; Cable entry from the top.<br />
&#8211; Reference standards CEI EN61921, IEC60439, IEC60831-1</p>
<hr />
<p><a href="/wp-content/uploads/2017/09/LND A 2014.pdf" target="_blank" rel="noopener">LND A 2014.pdf</a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LEONARDO  B</title>
		<link>https://www.varelit.com/en/prodotto/leonardo-b/</link>
		
		<dc:creator><![CDATA[varel]]></dc:creator>
		<pubDate>Sat, 09 Dec 2017 13:04:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.varelit.com/prodotto/leonardo-b/</guid>

					<description><![CDATA[LEONARDO B]]></description>
										<content:encoded><![CDATA[<p>Maximum installable power 100 kVAr.</p>
<p>Fully modular automatic power factor correction equipment LEONARDO type in painted metal plate RAL 7035, double front panel with screw fastening.</p>
<p>Dimensions (mm) 500x684x400 HxWxD</p>
<p>Possibility to install up to 4 different Jolly units of different powers. Available on request: IP 54 protection, 230 V rated power supply</p>
<p>TECHNICAL DATA:</p>
<p>&#8211; Three-pole disconnector with a door blocking system.</p>
<p>&#8211; Automatic regulator RDM 4 standard up to 4 batteries, with backlit LCD display for a better vision of the data.</p>
<p>&#8211; Auxiliary circuits 400 V (230V or 110 V available on request).</p>
<p>&#8211; Fuse protection for the auxiliary circuits.</p>
<p>&#8211; Rapid plug and play connectors for inserting the Jolly units.</p>
<p>&#8211; Connection with fireproof N07VK cables.</p>
<p>&#8211; Natural ventilation (LNDA-B-C) or forced ventilation with fan on the top (LND-D-F).</p>
<p>&#8211; Internal wall mounted installation Cable entry from the top.</p>
<p>&#8211; Reference standards CEI EN61921, IEC60439, IEC60831-1</p>
<hr />
<p><a href="/wp-content/uploads/2017/09/LND B 2015.pdf" target="_blank" rel="noopener">LND B 2015.pdf</a></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>LEONARDO  C</title>
		<link>https://www.varelit.com/en/prodotto/leonardo-c/</link>
		
		<dc:creator><![CDATA[varel]]></dc:creator>
		<pubDate>Sat, 09 Dec 2017 13:04:09 +0000</pubDate>
				<guid isPermaLink="false">https://www.varelit.com/prodotto/leonardo-c/</guid>

					<description><![CDATA[LEONARDO C]]></description>
										<content:encoded><![CDATA[<p>Maximum installable power 175 kVAr.<br />
Fully modular automatic power factor correction equipment LEONARDO type in painted metal plate RAL 7035, on a galvanized metal sheet base and double front panels with screw fastening.<br />
Dimensions (mm) 810x685x360 HxWxD<br />
Possibility to install up to 14 different Jolly units of different powers. Available on request: IP 54 protection, 230 V rated power supply<br />
TECHNICAL DATA:<br />
&#8211; Three-pole disconnector with a door blocking system.<br />
&#8211; Automatic regulator RDM 6 standard up to 6 batteries, with backlit LCD display for a better vision of the data.<br />
&#8211; Auxiliary circuits 400 V (230V or 110 V available on request).<br />
&#8211; Fuse protection for the auxiliary circuits.<br />
&#8211; Rapid plug and play connectors for inserting the Jolly units.<br />
&#8211; Connection with fireproof N07VK cables.<br />
&#8211; Natural ventilation.<br />
&#8211; Internal wall mounted installation<br />
&#8211; Cable entry from the top.<br />
&#8211; Reference standards CEI EN61921, IEC60439, IEC60831-1</p>
<hr />
<p><a href="/wp-content/uploads/2017/09/LND C 2014.pdf" target="_blank" rel="noopener">LND C 2014.pdf</a></p>
]]></content:encoded>
					
		
		
			</item>